Are there fire proof safes?
No. The fire safes that you find are "fire resistant" safes. There
is no safe that can protect your valuables indefinitely against fire. Each
fire resistant safe is tested against fire and given an hourly rating at
350° internal temperature. Many safes give little burglary protection
as just a fire safe. This is why many people opt for a fire safe with a
U.L. burglary certification appropriate for what the safe will be used for.
Is a regular fire safe appropriate to store computer data?
No. A standard fire safe is tested and rated to keep the interior of the
safe at 350° for a certain amount of time. Paper burns at 450°.
Media safes are tested and rated to keep the interior of the safe at 125°
or 150° (depending on the safe) for a certain period of time. Media
protection can be attained in several different ways - Some pricey, some
very affordable. Ask a sales rep.
What is the difference between a burglary and fire safe?
A burglary safe has been tested and rated against an opening attack. A
fire safe has been tested and rated against a fire. The following are
a list of the U.L. Laboratory Rating Labels and their performance requirements.
Burglary Classification TL-15
Signifies a combination-locked safe designed to offer a limited degree
of protection against attack by common mechanical and electrical hand
tools and any combination of these means. Has sucessfully resisted entry*
for a net working time of 15 minutes when attacked with common hand
tools, picking tools, mechanical or portable electric tools, grinding
points, carbide drills, pressure applying devices or mechanisms.
Burglary Classification TL-30
Signifies a combination-locked safe designed to offer a moderate degree
of protection against attack by common mechanical and electrical tools
and any combination of these means. Has successfully resisted entry*
for a net working time of 30 minutes when attacked with common hand
tools, picking tools, mechanical or portable electric tools, grinding
points, carbide drills, pressure applying devices or mechanisms, abrasive
cutting wheels and power saws.
Burglary Classification TRTL-30
Signifies combination locked safe designed to offer a moderate degree
of protection against attack by common mechanical and electrical tools
and cutting tools and cutting tourches and any combination of these
means. Has successfully resisted entry* for a net working time of 30
minutes when attacked with common hand tools, picking tools, mechanical
or portable electric tools, grinding points, carbide drills, pressure
applying devices or mechanisms, abrasive cutting wheels, power saws,
impact tools and oxy-fuel gas cutting or welding torch (test gas limited
to 1000 cubic feet combined total oxygen and fuel gas.)
Burglary Classification TRTL-60
Signifies a combination-locked safe designed to offer a high degree
of protection against attack by common mechanical and electrical tools
and cutting torches and any combination of these means. Has successfully
resisted entry* for a net working time of 60 minutes when attacked with
common hand tools, picking tools, mechanical or portable electric tools,
grinding points, carbide drills, pressure applying devices or mechanisms,
abrasive cutting wheels, power saws, impact tools and oxy-fuel gas cutting
or welding torch (test gas limited to 1000 cubic feet combined total
oxygen and fuel gas).
Burglary Classification TXTL-60
Signifies a combination-locked safe designed to offer a high degree
of protection against attack by common mechanical and electrical tools
and cutting tools and cutting torches, high explosives and any combination
of these means. Has successfully resisted entry* for a net working time
of 60 minutes when attacked with common hand tools, picking tools, mechanical
or portable electric tools, grinding points, carbide drills, pressure
applying devices or mechanisms, abrasive cutting wheels, power saws,
impact tools, and oxy-fuel gas cutting or welding torch, nitroglycerin
or other high explosives equivalent to not more than 4 ounces of nitroglycerin
in one charge (entire test must not use more explosive than that equivalent
to 8 ounces of nitroglycerin).
*Entry means for:
Safes classed TL-15 and TL-30 - Opening the door or making a 6 square
inch opening entirely through the door or front face.
Safes classed TRTL-30-, TRTL-60, and TXTL-60 - Opening or making a 2
inch square opening entirely through the door or body.
Guide
to Safe Labels - U.L. Fire Resistive Container Classifications
U.L. Label Type Class 150 - 4 hours (Insulated Record
containers)
Maintain an interior temperature less than 150°F and an interior relative
humidity less than 85% when exposed to fire as per the Standard Time Temperature
Curve for 4 hours to 2000°F Successfully undergo all other requirements
for the Fire Endurance Test**, the Explosion Hazard Test*, the Humidity
Test**** and the Fire & Impact Test*** (seperately or combined*****).
Basically, no explosion through 30 minutes of exposure to a 2000°F
fire, an immediate 30' drop test, and a standard reheating for 60 minutes
to 1700°.
U.L. Label Type Class 150 - 2 hours (Insulated Record
containers)
Maintain an interior temperature less than 150°F and an interior
relative humidity less than 85% when exposed to fire as per the Standard
Time Temperature Curve for 3 hours to 1850°F. Successfully undergo
all other requirements for the Fire Endurance Test**, the Explosion Hazard
Test*, the Humidity Test**** and the Fire & Impact Test*** (seperately
of combined*****). Basically, no explosion through 30 minutes of exposure
to a 2000°F fire, 15 minutes of standard exposure to 1638°F, an
immediate 30' drop test, and a standard reheating for 60 minutes to 1638°F.
U.L. Label Type Class 150 - 1 hour (Insulated Record
containers)
Maintain an interior temperature less than 150°F and an interior
relative humidity less than 85% when exposed to fire as per the Standard
Time Temperature Curve for 3 hours to 1700°F. Successfully undergo
all other requirements for the Fire Endurance Test**, the Explosion Hazard
Test*, the Humidity Test**** and the Fire & Impact Test*** (seperately
or combined*****). Basically, no explosion through 30 minutes of exposure
to a 2000°F fire, an immediate 30' drop test, and a standard reheating
for 30 minutes to 1550°F.
U.L. Label Type Class 350 - 4 hours (Fire resistants
safes)
Maintain an interior temperature less than 350°F when exposed to fire
as per the Standard Time Temperature Curve for 4 hours to 2000°F.
Successfully undergo all other requirements for the Fire Endurance Test**,
the Explosion Hazard Test*, the Humidity Test**** and the Fire & Impact
Test*** (seperately or combined*****). Basically, no explosion through
30 minutes of exposure to a 2000°F fire, 30 minutes of standard exposure
to 1700°F, an immediate 30' drop test, and a standard reheating for
30 minutes to 1700°F.
U.L. Label Type Class 350 - 2 hours (Fire resistants
safes)
Maintain an interior temperature less than 350°F when exposed to fire
as per the Standard Time Temperature Curve for 2 hours to 1850°F.
Successfully undergo all other requirements for the Fire Endurance Test**,
the Explosion Hazard Test*, the Humidity Test**** and the Fire & Impact
Test*** (seperately or combined*****). Basically, no explosion through
30 minutes of exposure to a 2000°F fire, 15 minutes of standard exposure
to 2000°, an immediate 30' drop test, and a standard reheating for
45 minutes to 1638°F.
U.L. Label Type Class 350 - 1 hours (Fire resistants
safes)
Maintain an interior temperature less than 350°F when exposed to fire
as per the Standard Time Temperature Curve for 1 hour to 1700°F. Successfully
undergo all other requirements for the Fire Endurance Test**, the Explosion
Hazard Test*, the Humidity Test**** and the Fire & Impact Test***
(seperately or combined*****). Basically, no explosion through 30 minutes
of exposure to a 2000°F fire, an immediate 30' drop test, and a standard
reheating for 30 minutes to 1550°F.
U.L.
Tests
* Explosion Hazard Test
An empty sample is closed, locked and placed into a furnace preheated
to 2000°F. This temperature is maintained for 30 minutes (20 minutes
for units rated1/2 hour) and if no explosion results, the unit is allowed
to cool without opening the furnace doors. Once cooled, the unit is opened,
dismantled and examinations made reguarding the heat insulating properties
of the sample such as condition of interior finish, security of interior
equipment, lock part fastenings, and any signs of undue transmission of
heat or moisture.
**Fire Endurance Tests
After the units' contents are placed inside and in contact with the interior
walls, the unit is closed, locked, and exposed to a uniformly distributed
fire. The temperature of which is regulated and increased according to
the Standard Time Temperature Curve summerized below. The fire is continued
for the period required for the classification desired and allowed to
cool without opening the furnace. The interior temperature is recorded
throughout the test and during the subsequent cooling period until a definite
drop is shown and must never exceed 150°F or 350°F as the case
may be. Once cooled, the unit is opened, dismantled and its contents examined
for usability. The units' locking mechanism and part fastenings are examined
for security and the interior examined for any visible evidence of undue
heat transmission. Regular production units must again pass the Fire Endurance
Test, 1 year after the first test or 1 year after production of the tested
unit began.
|
Abbreviated Time Temperature Curve
|
| Minutes |
Temperature degrees F |
Minutes |
Temperature degrees F |
| 5 |
1000° |
120 |
1850° |
|
30
|
1550° |
180 |
1925° |
| 60 |
1700° |
240 |
2000° |
***Fire & Impact Test
After the units' contents are placed inside and in contact with the interior
walls, the unit is closed, locked and exposed to the Standard time as
in the Fire Endurance Test for the period of time stated for that classification.
Within two minutes, the unit is removed from the furnace and dropped 30'
onto a riprap of brick on a heavy concrete base. After impact, the unit
is examined for deformation, rupture of parts, damaged insulation, and
any other openings into the interior of the unit. When sufficently cooled
for handling the unit is inverted, reheated for the time stated and allowed
to cool without opening the furnace doors. Once cooled, the unit is opened,
dimantled and examinations made reguarding the heat insulating properties
of the sample such as uasability of contents, condition of the interior
finish, security of locks, part fastenings and any signs of undue transmission
of heat or moisture.
****Humidity Test
After pre-conditioning, the unit is heated for 12 hours to obtain an interior
temperature of 70+or- 5°F and a relative humidity of 50 +or- 15 percent.
The unit must successfully maintain an interior relative humidity less
than 85% during that part of the cooling period when the interior temperature
is above 120°F. Units are also examined for any signs of moisture
penetration into the interior.
*****Combined Explosion Hazard - Impact Test
At the manufacturer's option, both the Fire-Impact Test and the Explosion
Hazard Test can be combined and conducted on one sample fire resistant
safe or insulated record container as follows. The Explosion Hazard Test
is first conducted. If no explosion results during 30 minutes at 2000°F,
the furnace temperatures are to be reduced to those of the Standard Test
Temperature Curve and the fire continued for an additional 30 minutes
for units to be rated 4 Hours, and for an additional 15 minutes for units
to be rated 2 Hours. No additional exposure is required for units to be
rated 1 Hour. After exposure to the fire for the total period necessary
for the classification desired, the furnace fire is to be extinguished
and the test sample withdrawn. Within 2 minutes, the unit is dropped from
30' into the riprap of brick on a heavy concrete base, examined, reheated,
and re-examined as per the requirements of the Fire And Impact Test.